主要特点 宽输出电压、电流范围:0-16 Vdc to 0-4000 Vdc 和 0-40 Adc to 0-24000 Adc 以标准的宽输入电压、频率范围: 从 380 Vac 到 480 Vac 频率: 50 Hz 和 60 Hz **的可编程和监测 I/O标准通讯接口:37针电路标准的光隔离的用户I / O界面,*额外的隔离电路 **的运作:高达92%的效率在满载情况下 RS232接口标配(标准SCPI命令):GPIB,USB,以太网,RS485接口可选 可选以太网LAN接口(LXI-certified Ethernet communications):内嵌web-server 过压过流保护关闭标准(OCT&OVT STD): 过压保护和过流保护机械接触器高速断开主输入 可回馈电网选件(内置Models 250 kW+): 电能可回馈电网功能选件(Power Cycle AC Grid),自动谐波消除平衡系统,产生(6n±1)-12/18/24/48个脉冲高级的回馈电网技术 IVI驱动程序:多种可视化编程应用可支持Labview,Labwindows/CVI,IVI驱动等 前面板计量校准: 100 kW Models指标 Model Voltage (Vdc) Current (Adc) Ripple (mVrms) Eff. % 3Φ Input Current (Aac) 380/415 V 440/480 V MTA16-6000 0-16 0-6000 35 90 191 165 MTA20-5000 0-20 0-5000 40 90 191 165 MTA32-3000 0-32 0-3000 40 90 191 165 MTA40-2500 0-40 0-2500 40 91 191 165 MTA50-2000 0-50 0-2000 50 91 191 165 MTA80-1250 0-80 0-1250 60 91 191 165 MTA100-1000 0-100 0-1000 60 91 186 160 MTA125-800 0-125 0-800 100 91 186 160 MTA160-620 0-160 0-620 120 91 186 160 MTA200-500 0-200 0-500 125 91 186 160 MTA250-400 0-250 0-400 130 92 186 160 MTA375-270 0-375 0-270 170 92 186 160 MTA400-250 0-400 0-250 180 92 186 160 MTA500-200 0-500 0-200 220 92 186 160 MTA600-160 0-600 0-160 250 92 186 160 MTA800-120 0-800 0-120 300 92 186 160 MTA1000-100 0-1000 0-100 400 92 186 160 MTA1250-80 0-1250 0-80 500 92 186 160 MTA1600-62 0-1600 0-62 600 92 186 160 MTA2000-50 0-2000 0-50 800 92 186 160 MTA2500-40 0-2500 0-40 900 92 186 160 MTA3000-32 0-3000 0-32 1000 92 186 160 MTA4000-24 0-4000 0-24 1100 92 186 160 详细指标Specifications Input Nominal Voltage3 phase, 3 wire + ground 380 VAC (operating range 342 - 418 VAC)415 VAC (operating range 373 - 456 VAC)440 VAC (operating range 396 - 484 VAC)480 VAC (operating range 432 - 528 VAC) Frequency 50 Hz (operating range 45 Hz - 55 Hz)60 Hz (operating range 54 Hz - 66 Hz) Power Factor > 92% at max. power 100 kW and 150 kW modules> 96% at maximum power 250 kW modules Environmental Operating Temperature 0°C to 50°C Storage Temperature -25°C to +85°C Air Cooling Front and rear intake, top exhaust Physical Power Input Phases Size (H" x W" x D") Weight 100 kW150 kW250 kW500 kW750 kW1000 kW 3Φ3Φ3Φ3Φ3Φ3Φ 62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm)62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm)62.5 x 72 x 31.5 in (158.8 x 182.9 x 80.0 cm)62.5 x 144 x 31.5 in (158.8 x 365.8 x 80.0 cm)62.5 x 216 x 31.5 in (158.8 x 548.7 x 80.0 cm)62.5 x 288 x 31.5 in (158.8 x 731.6 x 80.0 cm) 1600 lbs (725.8 kg)2100 lbs (952.5 kg)3300 lbs (1496.9 kg)6600 lbs (2993.7 kg)9900 lbs (4490.6 kg)13200 lbs (5987.4 kg) Output Ripple See Model Charts Line Regulation Voltage Mode: ± 0.004% of full scaleCurrent Mode: ± 0.02% of full scale Load Regulation Voltage Mode: ± 0.01% of full scaleCurrent Mode: ± 0.04% of full scale Load Transient Response 2 ms to recover within ±1% of regulated output with a 50% to ** or ** to 50% step load change Efficiency ≥ 90%; See Model Charts Stability ± 0.10% for 8 hrs. after 30 min. warmup Isolation User inputs and outputs:referenced to Earth groundMaximum input voltage to ground:±2500 VacMaximum output voltage to ground:±1000 Vdc for models less than or equal to 1000 Vdc,±4000 Vdc for models greater than 1000 Vdc. Maximum Slew Rate Standard Models:100 ms for an output voltage change from 0 to 63%,100 ms for an output current change from 0 to 63%.With High Slew Rate Option (+HS):6 ms for an output voltage change from 0 to 63%,12 ms for an output current change from 0 to 63%. Bandwidth Standard Models:3 Hz with remote analog voltage programming,2 Hz with remote analog current programming.With High Slew Rate Option (+HS):60 Hz with remote analog voltage programming,45 Hz with remote analog current programming. Programming Levels and Accuracy of Full Scale VoltageSet Point CurrentSet Point OVTSet Point OCTSet Point Remote Analog Programming Accuracy ± 0.075% ± 0.075% ± 0.075% ± 0.075% Digital Programming Accuracy ± 0.075% ± 0.075% ± 0.075% ± 0.075% Remote Analog Programming Levels 0 - 10.0 Vdc 0 - 10.0 Vdc 0 - 10.0 Vdc 0 - 10.0 Vdc Monitoring Levels and Accuracy of Full Scale Output Voltage Output Current Remote Analog Monitoring Accuracy ± 0.2% ± 0.2% Digital Monitoring Accuracy ± 0.2% ± 0.2% Remote Analog Monitoring Levels 0 - 10.0 V 0 - 10.0 V Control Limits Remote Sense Limits 3% maximum voltage drop from output terminals to load. Remote sense is not available for models with output voltages greater than 1000 Vdc. Period Programming Limits Minimum period: 10 msecMaximum Period: 9997 sec or 2.77 hours Digital control inputs and outputs limits Input voltage: 0 to 5 Vdc, 10K input impedance;Output voltage: 0 to 5 Vdc, 5 mA drive capacity5 V supply: 25 mA.